This station has all the
friendly features of a monitoring station. The 16
universal analogue inputs are software programmable using the
user friendly MicroScan software. Each input can be configures
for any of the following inputs: Thermocouple, RTD Pt100,
Pt1000, mA, MV & V. The wide choice of spans ensures high
accuracy. The analogue inputs on the
2100-A16 can be
expanded up to 76 using the 2100-M Input
Multiplexers.
The 2 relay contact outputs perform an alarm or control
function. Output expansion is available using the
2100-R, 16 relay output expansion module. This allows
the station to stand alone as a 16 channel controller with the
relay outputs used for control or alarm or a combination of
both. The set point (SV) for each of the 16 controllers, is
downloaded from the user friendly MicroScan software Mimic
package, and held in permanent memory on the
2100-A16.
Other controller prameters include, output switching
differential, auto/manual and manual settings of output. the
16 controllers/alarms will operate unaffected by computer
power downs, or reboots etc.
The optional 2100-E memory expansion card
is designed to allow the 2100-A16
to stand alone, retaining its data collected for
intermittent download.
|
| Specifications: |
| Analogue Outputs: |
16 Differential, 16 Bit
A/D, Each Input can be individually software selected and
scaled within the following span limits. |
| mV: |
-500~500mV |
| V: |
-15~15V |
| mA: |
-100~100mA (4~20mA default) |
| RTD (Pt100 or
Pt1000): |
-200~850°C
(-330~1550°F) |
(Note: on bd selectable. All
Pt selections will be either Pt100 or
Pt1000) |
Thermocouple: K&N: J: T: R&S: B: E: |
saas:dss -200~1300°C
(-330~2400°F) -200~1200°C
(-330~2200°F) -200~400°C
(-330~750°F) 0~1700°C
(0~3000°F) 250~1800°C
(500~3000°F) -200~900°C
(-330~1650°F) |
| Differential
Inputs: |
18V DC peak between any 2
channels, mV, V, mA, T/C ie:18V DC peak between any 2 points on
the input terminals RTD (Pt100)
Single Ended |
| Accuracy: |
± 0.1% FSO typical |
| Digital Inputs: |
3 Digital Opto Isolated
Inputs 5 to 30V DC |
| Max
Input Frequency: |
100 Hz typical on/off and count LED
indication on each channel |
| Relay Outputs: |
2 normally open contact
outputs, form A Contact rating = 30V
DC 1 amp LED Indication on each
channel |
| 16 on
Board Controllers: |
Up to 16 with 2100-R fitted |
| Communications: |
Isolated RS422, RS485,
RS232 |
| Comms
Baud Rate: |
19200, 9600, 4800, 2400
selectable (radio & modem
compatable) |
| Power Supply: |
80~265V
AC/DC 20~80V AC/DC
selectable 8~30V AC/DC
optional Power Supply Consumption
5VA |
| Expansion
Options: |
|
| Option 1: |
Input
Expansion. Supports up to four 2100-M input multiplexers.
Maximum distance between
2100-A16 & 2100-M =
50m. |
| Option 2: |
Output Expansion: 2100-R relay
output module. |
| Option 3: |
Memory Expansion. 2100-E memory
expansion card for `stand alone´
monitoring. Storage capacity = 2000 readings
of each input. Options 1 & 2 are not available with this
option fitted. |
|
|
|