Action indication:
Display accuracy:
Display accuracy range:
Display resolution:
Measured value display range:
Display update cycle:
Setting
Setting:
Setting range:
Input
Type of input:
Thermocouple:
External resistance:
Input impedance:
Burnout:
Cold junction
Temperature
compensation
accuracy:
R.T.D.:
Amperage:
Lead wire tolerable resistance:
Voltage
(mV):
(V):
Input impedance:
Current:
Input impedance
Input scaling function:
Scaling range:
Span:
Position of Decimal point:
Sampling cycle:
PV bias:
PV filter:
Isolation:
Alarm output (option)
Number of alarm points:
Alarm type:
Alarm setting range:
Alarm action:
Alarm sensitivity:
Alarm output/ rating:
Alarm output update cycle:
Analog output (option)
Analog output type:
Output resolution:
Output accuracy:
Output scaling:
Output update cycle:
Communication (option)
Communication type:
Communication system:
Communication speed:
Data bit length:
Communication address:
Multi-drop connection:
Communication delay:
Others
Data storage:
Ambient conditions for use
Temperature and Humidity:
Height:
Installation category:
Degree of pollution:
Power supply:
voltage:
Power consumption:
Applicable standard
Safety:
EMC:
Dust proof / Drip proof:
Insulation resistance:
Dielectric strength:
Case material :
External dimensions:
Mounting:
Panel thickness :
Panel cutout :
Weight:
By four (4) front key switches
Same as measuring range
Multiple input of Thermocouple, R.T.D., Voltage
(mV, V) and Current (mA)
B, R, S, K, E, J, T, N, {U, L (DIN 43710)},
WRe5-26 - Refer to measuring range code table
100 Ohm max.
500K Ohm Min.
Standard feature (Up-scale)
± l °C (18 ~ 28 °C range)
±2 °C (5 ~ 18 °C, 28 ~ 45 °C range)
(±5 °C to the negative side of measuring range in
case of T and U input)
JIS Pt100 Ohm 3-wire type
Approx. 0.25mA
5 Ohm max. / wire (3 lead wire should have same
resistance) When the resistance value of each
wire is same 0 ~ 5 Ohm: 0.05 °C, 5 ~ 10 Ohm:
0.2 °C, 10 ~ 20 Ohm: 0.6 °C, 20 ~ 30 Ohm:
1.4 °C max.
0 ~ 10mV DC
0 ~ 5V,1 ~ 5V, 0 ~ 10V DC
500K Ohm min.
4 ~ 20mA DC
250 Ohm [A shunt resistor (option) needs to be
connected to the terminal]
Scaling possible for voltage (mV, V) or current
(mA) input and inverse scaling possible.
-1999 ~ 9999 unit
10 ~ 5000 unit
None, 0.0, 0.00, 0.000
0.5 seconds
±200 unit
0 ~ 100 seconds (0 = without filter)
Between input and analog output
2 (AL1 and AL2) for both normal open and Common
Selectable from combinations of the following 4 types:
Higher limit absolute value w/out inhibit action
Higher limit absolute value with inhibit action
Lower limit absolute value w/out inhibit action
Lower limit absolute value with inhibit action
Within measuring range or within full scaling range
ON-OFF action
1 ~ 999 unit Within measuring range
Contact 1a (common) / 240V, AC 1.5A (resistive load)
0.5 second
0 ~ 10mV DC (output resistance: 10 Ohm)
0 ~ 10V DC (load current: 1rnA max)
4 ~ 20mA DC (load resistance 300 Ohm max)
Approx. 0.03% (1/3000)
±(0.3%FS + 1 digit) of display value
Within measuring range (inverse scaling possible)
0.5 seconds
RS-232C, RS-485
Half duplex start-stop synchronized system
1200, 2400, 4800, 9600, 19200 bps
7 bit even parity 1 stop bit
8 bit non parity 1 stop bit
1 ~ 255 address
31 max (with RS-485)
0 ~ 50.0 milli-seconds
By non-volatile memory (EEPROM)
-10 ~ 50 C/90%RH max (on condition that there is no dew condensation)
2000m above sea level or lower
Category II
Degree 2
100 ~ 240V AC±10%, 50/60Hz
24V AC/DC ±10%
11VA (AC) max,7W (DC) max.
IEC 1010-1, 1992
EMI (emission) EN50081-2,1993
EMS (immunity) EN50082-2,1995
(EMC testing Display accuracy: +5% FS)
IP66 (Complies w/ the IEC 529-1P66)
Between input/output terminal and
power supply terminal: 500V DC 20M Ohm min.
Between input/output terminal and
protective conductor terminal: 500V DC 20M Ohm min.
1 min. at 2300V AC between input/output terminal and power supply terminal
1 min. at l500V AC between power supply terminal and protective conductor
terminal
PPO resin molding (equivalent to UL94V-1)
H48 x W96 x D111 mm
Push-in panel (one-touch mount)
1.0 ~ 4.0 mm
H45 x W92 mm
Approx. 250g
Multi-Input & Multi-Range:
Thermocouples, RTDs, Voltage or Scaleable 4~20 mA DC
Input Voltage:
100 ~240 VAC or 24 VAC / 24 VDC
Front Panel:
Drip Proff and Dust Proof (IP66)
Display:
Over sized - 20MM (0.79") H
Optional Features:
High and Low Alarms - Individually set
Analog Output - Scaleable within Measuring Range
Computer Interface: RS232C or RS485
24 VAC / 24 VDC
CE Approved & UL/CSA Pending
IN PDF FORMAT |
||
| Or View Below for Essential Data | SD16 High Res Photo |