Display
•Digital display:

•Action indication:

 

•Display accuracy:

 

 

 

•Display accuracy range:

•Display resolution:

•Measured value display range:

 

 

•Display update cycle:



Setting
•Setting:

•Setting range:


Input
•Type of input:


•Thermocouple:


External resistance:

Input impedance:

Burnout:

Cold junction
Temperature
compensation
accuracy:

•R.T.D.:

Amperage:

Lead wire tolerable resistance:

 

 

•Voltage
(mV):

(V):

Input impedance:

•Current:

Input impedance


•Input scaling function:


Scaling range:

Span:

Position of Decimal point:

•Sampling cycle:

•PV bias:

•PV filter:

•Isolation:

Alarm output (option)
•Number of alarm points:

•Alarm type:

 

 

•Alarm setting range:

•Alarm action:

•Alarm sensitivity:

•Alarm output/ rating:

•Alarm output update cycle:

Analog output (option)
•Analog output type:



•Output resolution:

•Output accuracy:

•Output scaling:

•Output update cycle:

Communication (option)
•Communication type:

•Communication system:

•Communication speed:

•Data bit length:


•Communication address:

•Multi-drop connection:

•Communication delay:

Others
•Data storage:

•Ambient conditions for use
Temperature and Humidity:


Height:

Installation category:

Degree of pollution:

•Power supply:
voltage:

•Power consumption:

•Applicable standard
Safety:

EMC:



•Dust proof / Drip proof:

•Insulation resistance:

 


•Dielectric strength:

 


•Case material :

•External dimensions:

•Mounting:

•Panel thickness :

•Panel cutout :

•Weight:


Process value (PV) 7 segment Red LED 4 digits (H: 20mm)

1 point of parameter display (SET) by green LED
1 point of communication display (COM) by green LED
2 points of alarm (AL1 / AL2) by red LED

±(0.3% FS + 1 digit) within measuring range
Excluding cold junction temperature compensation accuracy in the case of thermocouple input
±5%FS for temperature below 400C of thermocouple B When the thermocouple [T, U] indication value,
is -100 ~ 0° C, ±0.5%FS and when it is below
-100 °C, ± l % FS

23 °C ± 5 °C (18 ~ 28 °C)

Depends on measuring range (0.001, 0.01, 0.1, 1)

-10 ~ 110% of measuring range (Accuracy
guaranteed for value is within measuring range only)
For R.T.D. input of –200 ~ 600 °C: 210 ~ 680 °C
For thermocouple [K] input of -199.9 ~ 800 °C:
-273.1 ~ 900.0 °C

0.5 ~ 5.0 Seconds (0.5 Steps)
When 0.5 second or more is set, there may occur
a difference among the displayed value, the
analog output and the communication data.

By four (4) front key switches

Same as measuring range

 

Multiple input of Thermocouple, R.T.D., Voltage
(mV, V) and Current (mA)

B, R, S, K, E, J, T, N, {U, L (DIN 43710)},
WRe5-26 - Refer to measuring range code table

100 Ohm max.

500K Ohm Min.

Standard feature (Up-scale)

± l °C (18 ~ 28 °C range)
±2 °C (5 ~ 18 °C, 28 ~ 45 °C range)
(±5 °C to the negative side of measuring range in
case of T and U input)

JIS Pt100 Ohm 3-wire type

Approx. 0.25mA

5 Ohm max. / wire (3 lead wire should have same
resistance) When the resistance value of each
wire is same 0 ~ 5 Ohm: 0.05 °C, 5 ~ 10 Ohm:
0.2 °C, 10 ~ 20 Ohm: 0.6 °C, 20 ~ 30 Ohm:
1.4 °C max.


0 ~ 10mV DC

0 ~ 5V,1 ~ 5V, 0 ~ 10V DC

500K Ohm min.

4 ~ 20mA DC

250 Ohm [A shunt resistor (option) needs to be
connected to the terminal]

Scaling possible for voltage (mV, V) or current
(mA) input and inverse scaling possible.

-1999 ~ 9999 unit

10 ~ 5000 unit

None, 0.0, 0.00, 0.000

0.5 seconds

±200 unit

0 ~ 100 seconds (0 = without filter)

Between input and analog output


2 (AL1 and AL2) for both normal open and Common

Selectable from combinations of the following 4 types:
Higher limit absolute value w/out inhibit action
Higher limit absolute value with inhibit action
Lower limit absolute value w/out inhibit action
Lower limit absolute value with inhibit action

Within measuring range or within full scaling range

ON-OFF action

1 ~ 999 unit Within measuring range

Contact 1a (common) / 240V, AC 1.5A (resistive load)

0.5 second


0 ~ 10mV DC (output resistance: 10 Ohm)
0 ~ 10V DC (load current: 1rnA max)
4 ~ 20mA DC (load resistance 300 Ohm max)

Approx. 0.03% (1/3000)

±(0.3%FS + 1 digit) of display value

Within measuring range (inverse scaling possible)

0.5 seconds


RS-232C, RS-485

Half duplex start-stop synchronized system

1200, 2400, 4800, 9600, 19200 bps

7 bit even parity 1 stop bit
8 bit non parity 1 stop bit

1 ~ 255 address

31 max (with RS-485)

0 ~ 50.0 milli-seconds


By non-volatile memory (EEPROM)

-10 ~ 50 C/90%RH max (on condition that there is no dew condensation)


2000m above sea level or lower

Category II

Degree 2

100 ~ 240V AC±10%, 50/60Hz
24V AC/DC ±10%

11VA (AC) max,7W (DC) max.


IEC 1010-1, 1992

EMI (emission) EN50081-2,1993
EMS (immunity) EN50082-2,1995
(EMC testing Display accuracy: +5% FS)

IP66 (Complies w/ the IEC 529-1P66)

Between input/output terminal and
power supply terminal: 500V DC 20M Ohm min.
Between input/output terminal and
protective conductor terminal: 500V DC 20M Ohm min.

1 min. at 2300V AC between input/output terminal and power supply terminal
1 min. at l500V AC between power supply terminal and protective conductor terminal

PPO resin molding (equivalent to UL94V-1)

H48 x W96 x D111 mm

Push-in panel (one-touch mount)

1.0 ~ 4.0 mm

H45 x W92 mm

Approx. 250g

FEATURES
Specifications

Low Cost:

From.....$149.00

Multi-Input & Multi-Range:

Thermocouples, RTDs, Voltage or Scaleable 4~20 mA DC

Input Voltage:

100 ~240 VAC or 24 VAC / 24 VDC

Front Panel:

Drip Proff and Dust Proof (IP66)

Display:

Over sized - 20MM (0.79") H

Optional Features:

• High and Low Alarms - Individually set
• Analog Output - Scaleable within Measuring Range
• Computer Interface: RS232C or RS485
• 24 VAC / 24 VDC
• CE Approved & UL/CSA Pending

DOWNLOAD COMPLETE PRODUCT SPECIFICATIONS IN PDF FORMAT DOWNLOAD INSTRUCTION MANUAL
IN PDF FORMAT
   
Or View Below for Essential Data   SD16 High Res Photo